RLS Wacon analytics have been involved in the online and manual testing of water constituents for more than 15 years. Our core competence includes the monitoring of total hardness for steam boiler systems. In addition, we offer a wide range of other parameters that are important for monitoring raw water, tap water and process water. Our online analyzers measure iron, alkalinity, alkalinity value and silicate. Our manual test sets cover more than 25 parameters. All our products are developed and manufactured in-house. A team of experts is available to answer all your questions.
We are looking for partners who use our products in their water systems. We are happy to work with local companies that are active in water treatment and conditioning in the areas mentioned above. We offer extensive options for customizing our products to your portfolio.
Address
Gropiusstr. 12
31137 Hildesheim
Germany
E-mail: sascha.matern@rls-wacon.de
Phone: +49 5121 281260
Internet: rls-wacon.de
Contact person:
Products & Services
RLS Wacon analytics have been involved in the online and manual testing of water constituents for more than 15 years. Our core competence includes the monitoring of total hardness for steam boiler systems. In addition, we offer a wide range of other parameters that are important for monitoring raw water, tap water and process water. Our online analyzers measure iron, alkalinity, alkalinity value and silicate. Our manual test sets cover more than 25 parameters. All our products are developed and manufactured in-house. A team of experts is available to answer all your questions.
We are looking for partners who use our products in their water systems. We are happy to work with local companies that are active in water treatment and conditioning in the areas mentioned above. We offer extensive options for customizing our products to your portfolio.
SYCON SiO2 - online analyzer for silica
The SYCON SiO2 is a photometric analyzer for monitoring silica (SiO2) in the ppm range (0.3 to 10 mg/l).
The special features are:
Compact design with easily accessible components
Tool-free maintenance of the measuring cell
Simple and intuitive operation via 8 buttons and large display
Durable and precise analysis technology
The following functions are reliably displayed by the SYCON Silicate analyzer:
Automatic zero point adjustment before each measurement
An individually adjustable limit value for alarm function via relay
Interfaces for measured value output
Measured values and log on SD card
Modbus RTU
Analog output 4 – 20 mA for measured value or detailed status messages
Four relay outputs for individual alarm and warning messages and for controlling other components (e.g. sample pump for unpressurized sample water)
Two programmable digital inputs
SYCON 2802 - online analyzer for hardness
The SYCON 2802 is a titration device for measuring water hardness or Alkalinity (Carbonate hardness). The device has four relays, making a large number of connection variants possible. The two input contacts make it possible, the RS485 interface with Modbus RTU protocol and a 4-20mA interface cover all needs of a modern online analyser.
The main features are:
Monitoring of a freely programmable limit value
Measurement of residual hardness, total hardness or Alkalinity (carbonate hardness - acid capacity)
Graphic display, menu navigation in many languages
Simple commissioning using the installation wizard
Documentation of all measurement results on an SD card
Low maintenance
Self-calibrating before each measurement
The included connections are:
Four potential-free outputs
A 4 -20 mA interface for measured value output or status message
Two input contacts
Modbus RTU
SYCON Fe - online analyzer for iron
The SYCON Fe is an analyzer for measuring free iron in a water sample. In addition to the usual relays and input contacts, the online analyzer has a 20 mA current and RS485 interface with Modbus RTU protocol.
The main features are:
Monitoring of a freely programmable limit value
Measurement of dissolved iron Fe (II and III)
Graphic display, menu navigation in many languages
Simple commissioning using the installation wizard
Documentation of all measurement results on an SD card
Low maintenance
Self-calibrating before each measurementConnections:
The included connections are:
Four potential-free outputs
A 4 -20 mA interface for measured value output or status message
Two input contacts
Modbus RTU
Manual test sets
CALDUR comprises test kits for the manual determination of water constituents. In addition to many standard rapid tests for checking residual hardness, total hardness, chlorine content and iron concentration, the CALDUR range also includes many test kits that are required for niche applications. All products in the CALDUR series are characterized in particular by their ease of use and very precise measurement point determination.
The test sets of the CALDUR scientific series are characterized by particularly easy handling and extremely high accuracy, which cannot be achieved with conventional manual test kits. This is achieved by dosing via a syringe, on the scale of which the measured value can be read directly - instead of counting drops.
TITRASENSE - cost-efficient hardness analyzer
The TitraSense is your smart choice for the exact online determination of water hardness in an industrial environment. It combines the proven precision of high-end titration devices with an outstanding price-performance ratio. Ideal for all who do not want to compromise on measurement accuracy but want to keep an eye on costs and for whom it is important that development and production come from a single source.
Application Areas:
Monitoring and controlling softening plants (e.g., demand-controlled regeneration triggering)
Quality control in reverse osmosis plants
Process water monitoring in building technology (heating, cooling, air conditioning)
Ensuring water quality in drinking water treatment
Monitoring of boiler feed water and steam generator plants to prevent deposits
Control of cooling circuits and cooling tower water
Technical Features:
Measuring Method: Colorimetric titration with automatic zero-point measurement
Measured Variable: Total hardness
Eleven measuring ranges covering from 0.02 to 500 ppm CaCO₃
Display & Operation: Graphic display with 8-key keypad
Outputs:
2 potential-free relays (changeover contact, 0.3 A / 125 VAC | 1 A / 30 VDC)
Relay 1: Limit alarm (water hardness)
Relay 2: Device malfunction (fail-safe)
Active current loop output 0/4 - 20 mA (measured value or status, max. load 750 Ω)
Input: Galvanically isolated input for potential-free contact (24 V auxiliary voltage)
Reagent:
Yield: Up to 13,000 analyses per bottle
Shelf Life: 24 months from date of manufacture
Functions:
Analysis Interval: Time-controlled (configurable, e.g., 5 min factory setting) or external start
Rinse Duration: Configurable (e.g., 15 - 1800 sec, 120 sec factory setting)
Data Storage: microSD card (measured values, errors, configuration)
Specifications:
Power Supply: 24 V DC
Power Consumption: approx. 25 VA during operation
Protection Class: IP43 (without front cover), IP54 (with front cover)
Ambient Temperature: 10 °C – 45 °C
Sample Water Temperature: 5 °C – 40 °C
Dimensions (W x H x D): 250 x 330 x 60 mm (without cover), 250 x 330 x 90 mm (with cover)
Weight: approx. 1.8 kg (with cover)